What is rail transit integrated monitoring system?

ISCS, generally speaking, is a highly integrated integrated integrated automatic monitoring system. Its main purpose is to form a unified hardware platform and software platform for monitoring layer by integrating multiple main strong and weak current systems of Metro. So as to realize the centralized monitoring and management function of the main strong and weak electric equipment of the subway, realize the related monitoring function of the train operation status and passenger flow statistics, and finally realize the information sharing and coordination and interaction functions between the relevant systems. Through the unified user interface of the integrated monitoring system, operation and management personnel can monitor and manage the operation of the entire line more conveniently and effectively.

Main subsystem function introduction

Environment and equipment integrated monitoring system (BAS): monitors the operation of each electromechanical equipment of the subway line, and controls the electromechanical equipment according to procedures and modes. Its data statistical management function is processed by the integrated monitoring (ISCS) system, and various graphs are generated to provide decision-making basis for rational operation and energy-saving management.

Power monitoring system (PSCADA): it adopts three-level control mode, namely remote control, centralized control on the control signal screen in the substation, and equipment body control. The three control modes are mutually locked. The system adopts the mode of centralized management and decentralized arrangement to realize the functions of system control, monitoring, measurement, protection, automatic control, automatic management and remote communication.

Automatic fire alarm system (FAS): including automatic fire alarm system, gas fire alarm control system, temperature sensing optical fiber system, emergency communication system. It is composed of trigger device, fire alarm device, fire alarm device and auxiliary function device. In the early stage of fire, the smoke, heat, flame and other physical quantities generated by combustion are transformed into electrical signals by fire detector, and then transmitted to the fire alarm controller, and the location and time of the fire are displayed at the same time.

Closed circuit television monitoring system (CCTV): CCTV closed circuit television monitoring system is composed of security network subsystem, security integrated management subsystem, integrated television monitoring subsystem, access control subsystem, depot / parking lot and elevated section intrusion detection subsystem, as well as station emergency alarm subsystem. It realizes the functions of access management, registration, real-time video monitoring and intrusion detection of key areas.

Passenger information system (PIs): it provides passengers with real-time and dynamic multimedia information such as train instructions, train arrival and departure time, train timetable, manager's announcement, government announcement, public service advertisement, TV Video Festival, etc.; it provides dynamic emergency evacuation prompt in case of fire, obstruction and terrorist attack.

Hotntech 17 inches IPC
for Rail transit integrated monitoring system

As an information monitoring platform, the industrial tablet computer is equipped with a high-resolution display screen embedded in the detection host, which can transmit the working information to the operator and the information security system. Due to the common wireless communication in railway system, the industrial tablet computer product should work stably in high-power RF system environment. In the rail transit system, vibration and shock are inevitable, so excellent shock and shock resistance is essential for the rail system. Hotntech industrial computers have excellent waterproof performance and impact resistance to ensure safe and reliable operation of the system. Rail vehicles often operate in a variable temperature environment, which means that all industrial tablet computers must support a wide operating temperature. Rail vehicles often operate in a variable temperature environment, which means that all industrial tablet computers must support a wide operating temperature. At the same time, the voltage also faces the challenge of sudden voltage surge when the vehicle starts or stops. Therefore, all devices must support wide power input. Fanless design is also necessary for industrial computers that are used in harsh environments. It can effectively reduce dust and avoid system failures. Hotntech industrial tablet computer is tailored for rail vehicle applications. It meets the critical requirements of rail vehicle applications. Its fanless design, good vibration and impact resistance can ensure The space still maintains safe, reliable, and efficient operation.